Home » News center » Sf1-h3
Sf1-h3
      Promulgator :admin      Time:2021-06-17
1. Certificate No.: crcc10209p10108r1s-2

Product Name: lamp for railway passenger car, bedside reading lamp for sleeping carriage

Specification and model: led-zt-dc110v; LED-ZT-DC48V

Certification standards and technical requirements: TB / t3085.2-2003;

Shanghai Dianjie industry and Trade Co., Ltd

Name of manufacturer: circuit breaker Industries Ltd

Manufacturing address: site 1: private bag 2016, isando 1600, ganuteng1401, South Africa (involving process: design, development and parts production process)

Site 2: site 22, plot 2, 3, 4, 12, hanyenye industrial estate, maputsoe, Lesotho, Lesotho (process involved: assembly and testing)

1. Certificate No.: crcc10209p10174r0s

Product Name: circuit breaker for railway signal AC circuit breaker

Specification and model: 1) qa-1 (13) rated voltage 240VAC; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50A; Rated breaking capacity 3KA;

2) Qa-3 (13) rated voltage 415vac; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50A; Rated breaking capacity 3KA;

3) Qf-1 (19) rated voltage 240VAC; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50a, 60A; Rated breaking capacity 6ka;

4) Qf-2 (19) rated voltage 415vac; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50a, 60A; Rated breaking capacity 6ka;

5) Qf-3 (19) rated voltage 415vac; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50a, 60A; Rated breaking capacity 6ka;

6) Qf-1 (26) rated voltage 240VAC; Rated current 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 6ka;

7) Qf-2 (26) rated voltage 415vac; Rated current 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 6ka;

8) Qf-3 (26) rated voltage 415vac; Rated current 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 6ka;

9) Bsh1pa rated voltage 240VAC; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A; Rated breaking capacity 1000A;

10) Sf1-g3 (1P) rated voltage AC240V; Rated current 1a, 5A, 10a, 15a, 20a, 25A, 30a, 35A, 40a, 45A, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 6ka;

11) Sf3-g3 (3P) rated voltage ac415v; Rated current 1a, 5A, 10a, 15a, 20a, 25A, 30a, 35A, 40a, 45A, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 6ka;

12) Sf1-h3 (1P) rated voltage dc125v; Rated current 1a, 5A, 10a, 15a, 20a, 25A, 30a, 35A, 40a, 45A, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 1.5kA;

13) Sf2-h3 (2P) rated voltage dc250v; Rated current 1a, 5A, 10a, 15a, 20a, 25A, 30a, 35A, 40a, 45A, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 1.5kA;

14) Sf2-g3 (2P) rated voltage AC240V; Rated current 1a, 5A, 10a, 15a, 20a, 25A, 30a, 35A, 40a, 45A, 50a, 60A, 70A, 80A, 90a, 100A; Rated breaking capacity 6ka;

Certification standards and technical requirements: yjxh [2007] No. 650;

Period of validity: February 26, 2010 to October 09, 2013

2. Certificate No.: crcc10209p10174r0s-1

Product Name: railway signal circuit breaker DC circuit breaker

Specification and model: 1) qdc-1 (13) rated voltage 80VDC; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50A; Rated breaking capacity 10kA;

2) Qdc-2 (26) rated voltage 250VDC; Rated current 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30a, 40a, 50A; Rated breaking capacity 10kA;

3) The rated voltage of bsh1dd is 50VDC; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A; Rated breaking capacity 500A;

4) Qdc-2 (13) rated voltage 220VDC; Rated current 0.5A, 1a, 2a, 3a, 5A, 6a, 8a, 10a, 15a, 20a, 25A, 30A; Rated breaking capacity 5ka;

Certification standards and technical requirements: yjxh [2007] No. 650;

1. Certificate No.: crcc10209p10178r1s

Product Name: anchorage for prestressed reinforcement (clip type)

Specification and model: yjm15-1bsm ~ yjm15-5bsm; YJM15-6BSM~YJM15-12BSM; YJM15-20BSM~YJM15-25BSM; YJM15-13BSM~YJM15-19BSM

Certification standards and technical requirements: TB / t3193-2008;

Period of validity: from February 9, 2010 to October 29, 2013

2. Certificate No.: crcc10209p10178r1s-1

Product Name: low retraction anchorage for prestressed tendons

Specification and model: dsm15-1 ~ dsm15-5

Certification standards and technical requirements: TB / t3193-2008;

1. Certificate No.: crcc10209p10194r0m

Product Name: train tail safety protection device

Specification and model: wzwm450 - Ⅰ (hook type) 450MHz; Wzwm800 - Ⅲ (hook type) 800MHz

Certification standards and technical requirements: TB / t2973-2006;

1. Certificate No.: crcc10210p10203r1m-2

Product Name: spring bar type I and type II fastener baffle seat (modified nylon 66)

Specification and model: 2-4 ᦇ raw materials are suitable for general areas

Certification standards and technical requirements: TB / t1495.5-2003;

1. Certificate No.: crcc110010700331

Product Name: railway signal transformer 25Hz Track transformer

Specification and model: bg2-130 / 25; BG3-130/25

Certification standards and technical requirements: TB / t2023-1988

Validity: the certificate will be suspended from February 9, 2010

1. Certificate No.: crcc110020700333

Product Name: AC / DC power supply lightning protector for railway electronic equipment

Specification and model: p-vms 75 (parallel, 10kA, ≤ 500V); P-vms 280 (parallel type, 20KA, limiting voltage ≤ 1000V)

Certification standards and technical requirements: TB / t2311-2002; TB/T30741-2003; T.Y. [2006] No.26

2. Certificate No.: crcc110020700334

Product Name: single phase power supply lightning protector for railway electronic equipment

Specification and model: p-vms 385 (parallel, 20KA, ≤ 1500V)

Certification standards and technical requirements: TB / t2311-2002; TB/T30741-2003; T.Y. [2006] No.26

3. Certificate No.: crcc110020700370

Product Name: channel lightning protector for railway signal equipment

Specification and model: p-vms 385 (parallel type 10kA, limiting voltage ≤ 1000V); P-vms 75 (parallel type 10kA, limiting voltage ≤ 330V);

P-vms 280 (parallel type 10kA limit voltage ≤ 700V)

Certification standards and technical requirements: TB / t2311-2002; TB/T3074-2003; T.Y. [2006] No.26;

1. Certificate No.: crcc140030600210

Product Name: Rail repair machinery hydraulic rail gap adjuster

Specification and model: aft-400d hydraulic rail gap adjuster

Certification standards and technical requirements: TB / t1405-1996; Yunji equipment [2005] No.170;

1. Certificate No.: crcc0700600241

Product Name: cable for low smoke and halogen free rail vehicle (2-48 core)

Specification and model: 1) wdz-slex-70-750 / wdz-s (P) lex-70-750, 2-7 cores, 0.75mm2-2.5mm2, 750V, 125 ℃, oil resistance class III;

2) Wdz-dck-125 type: 3-core, wire diameter 0.75-16mm2, 750V, 125 ℃, oil resistance class III;

3) Ka-dt-rfe / ka-dt-rfpe 2-7 core, 0.5mm2-2.5mm2, 750V, 125 ℃, oil resistance class III

Certification standards and technical requirements: TB / t1484-2001

2. Certificate No.: crcc0700600240

Product Name: cable for low smoke and halogen free rail vehicle (single core)

Specification and model: wdz-dcyj-125 type, 1.0mm2-240mm2, 750V, 1500V, 125 ℃, oil resistance class III

Certification standards and technical requirements: TB / t1484-2001
Next:TGPZ DP1
Previous:Lq-24xc
 
No comment
Total 0 records, divided into1 pages. First Prev Next Last
Business time
9:00-22:00
  • Email:support@rig123.com